Our handheld digital temperature calibrators provide highly portable laboratory-grade calibrations with leading accuracy and battery life. These calibrators can be used on-site to perform calibrations and verifications of thermocouples, temperature transmitters, indicators, process controllers and displays with lab-grade accuracy in the varied conditions found on the plant floor. Ideal for verifying temperature sensors, controllers, thermocouples, heating/ventilation, and climate control systems in aerospace, food & beverage, automotive, plastics, and chemical plant applications.
 

Eigenschaften

  • Source Accuracy: ±0.003% +5 µV
  • Temperature Calibrator Resolution: 0.01 ⁰
  • 10X Battery Life
  • Temperature Calibrator Features Simultaneous Source/Measure
  • MIL-STD Durability
  • ISO 17025 Cal standard; AMS 2750 Cal optional
  • Easy One-Hand Operation
  • CE, Complies with 47 CFR Part 15 of the FCC rules, Class B

Vorteile

  • Source and measure using one instrument
  • Superior accuracy assures your thermal equipment is working properly
  • Automatic ambient temperature compensation maintains accuracy in diverse conditions
  • One-key operation for common industry calibrations
  • Sealed keypad and contoured surfaces for easy cleaning
  • Preset options foster quick calibration for different equipment
  • Long battery life and easily replaced batteries keep your calibrator in continuous operation

Spezifikationen

Basic Accuracy: 0.005%
Connector Type: Mini-TC
Datalogging: No
Betriebstemperatur (°C): -20 to 55 ⁰C
Range: 15 to 85 mV
Auflösung (°C): 1 µV, 0.1⁰
Temp. Scale: C, F, K, mV

Lagerbestand prüfen

Modellnummer
Accuracy No. of TCs Supported Range Resolution Temp. Scale Kaufen
940A Active, Kontakt
J,K,T,E Thermocouple Calibrator + mV
±(0.005% rdg + 5µV) 4 15 to 85 mV 1 µV, 0.1⁰ C, F, K, mV Kaufen
945A Active, Kontakt
14 Thermocouple Calibrator + mV
±(0.005% rdg + 5µV) 14 15 to 85 mV 1 µV, 0.1⁰ C, F, K, mV Kaufen
945-2750 Active, Kontakt
AMS2750E Cal Option
Kaufen

Recommended Probes (Note, calibrators do not include temperature probes.)

Accessories Stock Check

Calibration Adapter Cable, Type E, Mini T/C Connector

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types: J, K, T, U, R/S or N. Sensor Type E.
 

Calibration Adapter Cable, Type J, Mini T/C Connector

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types:  K, T, E, U, R/S or N. Sensor Type J.

Calibration Adapter Cable, Type K, Mini T/C Connector 

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types: J, T, E, U, R/S or N. Sensor Type K.

Calibration Adapter Cable, Type N, Mini T/C Connector

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types:  K, T, E, J, U, or R/S . Sensor Type N. 
 

Calibration Adapter Cable, Type R/S. Mini T/C Connector

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types:  K, T, E, J, U or N. Sensor Type R/S

Calibration Adapter Cable, Type T. Mini T/C Connector

For use with TEGAM temperature calibrators. The Calibration Kit includes four 3’ cal cables of each Type K, J, T & E terminated with a male MTC connector and copper alligator clips; a 9K002MTC36 3’ Type K wire thermocouple sensor; all packaged in a 911-911 foam-filled hard carry case with room for your temperature calibrator, calibration cables, temperature probes and other small tools and accessories.

Calibration Adapter Cable, Type U. Mini T/C Connector

For use with TEGAM Thermocouple Calibrators. Includes a 3’ calibration cable terminated with a male MTC and ¼” spade lug; a standard thermocouple connector; and a standard to male mini adapter. Also Available in Types:  K, T, E, J, R/S or N. Sensor Type U. 

Alligator Calibration Cable Kit, T/C Types J/K/T/E

For use with TEGAM temperature calibrators. The Calibration Kit includes four 3’ cal cables of each Type K, J, T & E terminated with a male MTC connector and copper alligator clips; a 9K002MTC36 3’ Type K wire thermocouple sensor; all packaged in a 911-911 foam-filled hard carry case with room for your temperature calibrator, calibration cables, temperature probes and other small tools and accessories.

SAE AMS 2750 Calibration Option (4 Thermocouples); 94x Series Calibrators
Belt Clip for 700 and 900 Series Meters

Factory or User Installed Belt Clip
This clip allows the user to attach a 700 or 900 series meter quickly and easily to a belt. Frees hands for other tasks. Can be installed at purchase of handheld meter or purchased and installed separately at a later date.
NOTE: This product is not compatible with the tilt stand or magnet holders.

Technical Specifications
Attaches easily to TEGAM’s 900 and 700 Series handheld meters
Frees operators’ hands for other tasks.

Belt Clip for 700 & 900 Series (User Installed)
Tilt Stand / Magnetic Hanger for 900 Series (Factory Installed)

Tilt Stand, Magnet, Hanger is an optional accessory for the TEGAM 911A, 912A, 931A or 932A handheld thermometers. It is Factory Installed with purchase of 900 series thermometer. The hanger attaches to the back of the handheld thermometer so that professionals may free their hands while taking temperature measurements.

Technical Specifications
Purchased with a thermocouple thermometer and IS installed prior to shipping
Attaches easily to the back of TEGAM’s 911A, 912A, 931A or 932A
Allows professionals to free their hands while taking temperature measurements
Versatile

Foam-filled Hard Carry Case for 900 Series

Foam-filled hard carry case is an optional accessory for the TEGAM 911B, 912B, 931B or 932B handheld digital thermometers and the TEGAM 940A or 945A handheld temperature calibrators.

The case has a place for your handheld instrument, probes, and additional batteries.

Technical Specifications
Durable
Custom fit
Protects Equipment

Tilt Stand / Magnetic Hanger for 900 Series (User Installed)

Tilt Stand, Magnet, Hanger is an optional accessory for the TEGAM 911B, 912B, 931B or 932B handheld thermometers.  The hanger attaches to the back of the handheld thermometer so that professionals may free free their hands while taking temperature measurements.

Technical Specifications
Product is individually packed and is NOT installed on a thermocouple thermometer
Attaches easily to the back of TEGAM’s 911B, 912B, 931B or 932B
Allows professionals to free their hands while taking temperature measurements
Versatile

SureGrip Cover, Intrinsically Safe

TEGAM’s SureGrip Cover is designed for a more secure grip to prevent instrument damage from dropping, and possesses elastic properties from non-silicone elastomer which also protect airframes and vehicles from tooling damage due to accidental impacts.
The SureGrip Cover fits our 700 Series Bond Meters and 900 Series Digital Thermometers.& Calibrators

Calibrator Accessories

Calibrator Accessories

Thermometry Accessories

Accessories for thermometers and Calibrators

GSAmart

Click here for government agency procurement support.
Visit GSAmart

Dienstleistungen

Calibration and Alignment

Advanced Energy has the tools and processes to ensure your equipment continues to meet its original specifications.  Our products are calibrated at global AE service sites with proprietary technology designed to exceed industry standards​.

Agreement Term Options

Repair

Our worldwide service centers provide fast cycle times, use only AE-qualified parts, and follow the original product's specifications and test procedures for the highest quality repair or calibration.

Agreement Term Options

24/5 Support verfügbar

Holen Sie sich Expertenrat von unseren Ingenieuren

Wir sind bestrebt, unseren Kunden einen hervorragenden Kundendienst und technischen Support zu bieten. Mit Live-Chat und Telefon-Support können Sie jederzeit einen qualifizierten Techniker um Hilfe bitten.
Jetzt Unterstützung anfordern